Model HE-3-SSV-CF Cryostat
|
|
Description:
The model HE-3-SSV-CF is a
continuous flow
He-3 cryostat. A hermetically sealed mechanical pump is employed
to circulate the He-3 and cool down the system to the base temperature.
He-3 condenses inside the 1 K pot before it enters the He-3 pot through
a condensing impedance. An external gas handling system with a
special liquid nitrogen cold trap is equipped to operate the cryostat.
Turbo pump can be added to further reduce the He-3 vapor pressure so
that the system will reach the lower base temperatures. The sample
is typically attached at the bottom of the He-3 pot inside the inner
vacuum chamber (IVC) can for cooling.
This system can also be
operated in the single shot mode for a lower base temperature of
~350 mK, in which case the holding time will be
three days or longer.
The He-3 pot is installed on
the system with an indium seal. It can be replaced with
the Janis model JDR-100 dilution stage, which will allow the system to
reach a base temperature near 10 mK.
|
|
This He-3 cryostat includes
the following components:
- 1 K pot
- He-3 pumping line
- He-3 condensing impedance
- He-3 pot
- He-3 return line
- Gas handling system
- Hermetically sealed pump
- Electrical controlling circuit with over-pressure
safety protection
- Operation test
Options:
- Resistive and/or
superconducting wires
- Coaxial cables
- IVC tail for
superconducting magnet
- Low eddy current cold
finger
- Liquid nitrogen shielded
dewar
- Automatic temperature
controller
- Superconducting magnet
- Magnet support with high
current leads
- Magnet power supply
- Helium level sensor and
read out
- Nitrogen level sensor and
read out
- Liquid helium transfer line
|
Performance Specification:
| Base
Temperature:
|
450 mK
|
|
Holding
Time at Base Temperature:
|
Continuously operated
|
| Sample
Space:
|
As required
|
|
Temperature Range:
|
0.45 K - 80 K (300 K
optional) |
|
|
|
|
 |
|
|
Table of Contents |
Pages |
Introduction |
1 |
Standard He-3 Cryostats |
HE-3-SSV Insert, Standard Sample Loading, Sample in Vacuum |
2 |
HE-3-SVSD Insert, Standard Sample Loading, Sample in Vacuum for He-4 Storage Dewar
 |
3 |
HE-3-SSXGAS Insert, Standard Sample Loading, Sample in Exchange Gas |
4 |
HE-3-XGHS Mini-Exchange-Gas Handling System |
5 |
HE-3-SOSV Cryostat, Standard Sample Loading, Optical, Sample in Vacuum |
6 |
HE-3-SOSV-S
Cryostat, Standard Sample Loading, Optical, Sample in Vacuum |
7 |
HE-3-SVC Cryostat, Standard Sample Loading, Sample in Vacuum, Compact for Detector Application |
8 |
HE-3-CCR-SSV Cryostat, Standard Sample Loading, Sample in Vacuum, Cryogen-free |
9 |
HE-3-SSV-CF Cryostat, Standard Sample Loading, Sample in Vacuum, Continuous Flow |
10 |
HE-3-TLSL Cryostat, Top Loading, Sample in He-3 Liquid |
11 |
HE-3-TLOSL Cryostat, Top Loading, Optical, Sample in He-3 Liquid |
12 |
HE-3-TLSV
Cryostat, Top Loading, Sample in Vacuum |
13 |
Gas Handling System for Top Loading He-3 Systems |
14 |
Special He-3 Cryostats |
HE-3-TLSL-NMR Cryostat, Top Loading, Sample in He-3 Liquid for NMR Experiments |
15 |
HE-3-TLSUHV-SPM Cryostat, Top Loading, Sample in UHV for Scanning Probe Microscope System |
16 |
HE-3-SSUHV-SPM/ESR Cryostat, Standard Sample Loading, Sample in UHV for Scanning Probe Microscope System and Electron Spin Resonance System |
17 |
HE-3-BLSUHV-STM Cryostat,
Bottom Loading, Sample in UHV for Scanning Tunneling Microscope System
|
18 |
JANIS RESEARCH COMPANY, INC.
2 Jewel Drive, P.O. Box 696
Wilmington, MA 01887-0696 USA
TEL: +1-978-657-8750 FAX: +1-978-658-0349
E-Mail: sales@janis.com
Policies
|
|