Model HE-3-SVC Cryostat
|
|
Description:
The model HE-3-SVC cryostat
is a compact He-3 unit designed for experiments that cannot accommodate
the larger height of the standard units. It is ideal for
installation on an optical table and is typically used for detector
cooling to He-3 temperatures. The sample or detector is attached
at the bottom of the He-3 pot inside the vacuum jacket of the cryostat,
and the system is often supplied with a window that provides optical
access to the He-3 cold finger. The cryostat includes a
superinsulated, liquid nitrogen shielded helium reservoir designed for
long hold times, consistent with the size of the unit. The He-3
gas is permanently contained in a storage volume attached to the outer
jacket of the unit.
|
This He-3 cryostat includes the
following components:
- Charcoal sorption pump with
heater and thermometer
- 1 K pot with thermometer
- He-3 pot with heater and
thermometer
- Permanently stored He-3 gas
- Liquid nitrogen
shielded dewar
- Operation test
Options:
- Resistive and/or
superconducting wires
- Coaxial cables
- Clear shots to sample area
- 1 K cold plate
- Automatic temperature
controller
- Helium level sensor and
read out
- Nitrogen level sensor and
read out
- Liquid helium
transfer line
|
Performance Specification:
| Base
Temperature:
|
270 mK
|
Holding
Time at Base Temperature: (without pumping the 1 K pot)
|
40 hours
|
Holding
Time at Base Temperature: (pumping the 1 K pot)
|
120 hours
|
| Temperature
Range:
|
0.27 K - 80 K (300 K
optional)
|
| Sample
Space:
|
As required
|
| Port
Size:
|
As required
|
|
|
|
Table of Contents |
Pages |
Introduction |
1 |
Standard He-3 Cryostats |
HE-3-SSV Insert, Standard Sample Loading, Sample in Vacuum |
2 |
HE-3-SVSD Insert, Standard Sample Loading, Sample in Vacuum for He-4 Storage Dewar
 |
3 |
HE-3-SSXGAS Insert, Standard Sample Loading, Sample in Exchange Gas |
4 |
HE-3-XGHS Mini-Exchange-Gas Handling System |
5 |
HE-3-SOSV Cryostat, Standard Sample Loading, Optical, Sample in Vacuum |
6 |
HE-3-SOSV-S
Cryostat, Standard Sample Loading, Optical, Sample in Vacuum |
7 |
HE-3-SVC Cryostat, Standard Sample Loading, Sample in Vacuum, Compact for Detector Application |
8 |
HE-3-CCR-SSV Cryostat, Standard Sample Loading, Sample in Vacuum, Cryogen-free |
9 |
HE-3-SSV-CF Cryostat, Standard Sample Loading, Sample in Vacuum, Continuous Flow |
10 |
HE-3-TLSL Cryostat, Top Loading, Sample in He-3 Liquid |
11 |
HE-3-TLOSL Cryostat, Top Loading, Optical, Sample in He-3 Liquid |
12 |
HE-3-TLSV
Cryostat, Top Loading, Sample in Vacuum |
13 |
Gas Handling System for Top Loading He-3 Systems |
14 |
Special He-3 Cryostats |
HE-3-TLSL-NMR Cryostat, Top Loading, Sample in He-3 Liquid for NMR Experiments |
15 |
HE-3-TLSUHV-SPM Cryostat, Top Loading, Sample in UHV for Scanning Probe Microscope System |
16 |
HE-3-SSUHV-SPM/ESR Cryostat, Standard Sample Loading, Sample in UHV for Scanning Probe Microscope System and Electron Spin Resonance System |
17 |
HE-3-BLSUHV-STM Cryostat,
Bottom Loading, Sample in UHV for Scanning Tunneling Microscope System
|
18 |
JANIS RESEARCH COMPANY, INC.
2 Jewel Drive, P.O. Box 696
Wilmington, MA 01887-0696 USA
TEL: +1-978-657-8750 FAX: +1-978-658-0349
E-Mail: sales@janis.com
Policies
|
|