Model HE-3-SSXGAS Insert
|
|
Description:
The model HE-3-SSXGAS insert is
designed for standard sample loading with sample in exchange gas.
The sample chamber is located at the bottom of the He-3 pot and exchange
gas is introduced into the sample chamber to aid in cooling down the sample.
A model
HE-3-XGHS
mini-exchange gas handling system is usually included at the top of the
insert to provide the exchange gas required for the experiment.
The design minimizes the cost of the expendable exchange gas for each run
to approximately $1.00 (depending on geographic location). This
He-3 insert is especially suited for experiments with very fragile samples
that cannot be bolted tightly to the sample holder.
This He-3 insert includes the
following components:
- Charcoal sorption pump with
heater and thermometer
- 1 K pot with thermometer
- He-3 pot with heater and
thermometer
- Permanently stored He-3 gas
- IVC can
- Sample chamber with
exchange gas
- Mini-exchange gas handling
system
- Operation test
|
Options:
- Resistive and/or
superconducting wires
- Coaxial cables
- IVC tail for
superconducting magnet
- Clear shots to sample area
- 1 K cold plate
- Low eddy current cold
finger
- Helium storage dewar
- Vapor cooled helium dewar
- Liquid nitrogen shielded
dewar
- Automatic temperature
controller
- Superconducting magnet
- Magnet support with high
current leads
- Magnet power supply
- Helium level sensor and
read out
- Nitrogen level sensor and
read out
- Liquid helium
transfer line
|
Performance Specification:
| Base
Temperature:
|
300 mK
|
Holding
Time at Base Temperature: (typical)
|
24 - 48 hours
(depending on amount of He-3 gas installed) |
| Temperature
Range:
|
0.3 K - 80 K (300 K
optional)
|
| Sample
Space:
|
as required
|
|
|
 |
|
|
Table of Contents |
Pages |
Introduction |
1 |
Standard He-3 Cryostats |
HE-3-SSV Insert, Standard Sample Loading, Sample in Vacuum |
2 |
HE-3-SVSD Insert, Standard Sample Loading, Sample in Vacuum for He-4 Storage Dewar
 |
3 |
HE-3-SSXGAS Insert, Standard Sample Loading, Sample in Exchange Gas |
4 |
HE-3-XGHS Mini-Exchange-Gas Handling System |
5 |
HE-3-SOSV Cryostat, Standard Sample Loading, Optical, Sample in Vacuum |
6 |
HE-3-SOSV-S Cryostat, Standard Sample Loading, Optical, Sample in Vacuum |
7 |
HE-3-SVC Cryostat, Standard Sample Loading, Sample in Vacuum, Compact for Detector Application |
8 |
HE-3-CCR-SSV Cryostat, Standard Sample Loading, Sample in Vacuum, Cryogen-free |
9 |
HE-3-SSV-CF Cryostat, Standard Sample Loading, Sample in Vacuum, Continuous Flow |
10 |
HE-3-TLSL Cryostat, Top Loading, Sample in He-3 Liquid |
11 |
HE-3-TLOSL Cryostat, Top Loading, Optical, Sample in He-3 Liquid |
12 |
HE-3-TLSV
Cryostat, Top Loading, Sample in Vacuum |
13 |
Gas Handling System for Top Loading He-3 Systems |
14 |
Special He-3 Cryostats |
HE-3-TLSL-NMR Cryostat, Top Loading, Sample in He-3 Liquid for NMR Experiments |
15 |
HE-3-TLSUHV-SPM Cryostat, Top Loading, Sample in UHV for Scanning Probe Microscope System |
16 |
HE-3-SSUHV-SPM/ESR Cryostat, Standard Sample Loading, Sample in UHV for Scanning Probe Microscope System and Electron Spin Resonance System |
17 |
HE-3-BLSUHV-STM Cryostat,
Bottom Loading, Sample in UHV for Scanning Tunneling Microscope System
|
18 |
JANIS RESEARCH COMPANY, INC.
2 Jewel Drive, P.O. Box 696
Wilmington, MA 01887-0696 USA
TEL: +1-978-657-8750 FAX: +1-978-658-0349
E-Mail: sales@janis.com