Accessories and Ancillary Equipment

High Vacuum Pumping Station

Turbomolecular pumping stations provide a convenient means for evacuating laboratory cryostats and transfer lines to high vacuum levels (< 10-6 Torr).  Turbopump stations include a turbopump controller, roughing/backing pump, vacuum gauging, as well as a five foot long flexible pumping line, and valves.  The turbopump module utilizes low maintenance ceramic bearings while the mechanical pump includes vibration absorbing mounting.  The entire pumping system is mounted on casters for easy movement throughout the laboratory.  Two standard configurations are described below.  Custom configurations can include larger pump capacities, different gauging, and various inlet flanges.

TP-70-2

  • Turbo pump with nominal
    52 liters/second capacity
  • 1.2 CFM mechanical roughing pump
  • Mounting frame, on casters with air-cooler
  • Wide range vacuum gauge (atmosphere to 10-8 Torr) with digital display
  • Programmable turbo and instrument controller (TIC) with three gauge inputs, relays
  • 5-foot flexible stainless steel pumping line
  • Vacuum isolation valve
TP-70-2 Turbomolecular Pumping Station, Janis Research, cryogenics

TP-70-2DR
(oil free system)

  • Turbo pump with nominal
    52 liters/second capacity
  • Universal voltage 1.2 m3/h dry diaphragm backing pump
  • Integral silencer built into exhaust
  • Mounting frame, on casters with air-cooler
  • Wide range vacuum gauge (atmosphere to 10-8 Torr) with digital display
  • Programmable turbo and instrument controller (TIC) with three gauge inputs, relays
  • RS-232C serial computer interface and software to control TIC
  • 5-foot flexible stainless steel pumping line
  • Vacuum isolation valve
TP-70-2-DR Oil Free Turbomolecular Pumping Station, Janis Research

TP-TW70H

  • Turbo pump with nominal
    60 liters/second capacity
  • 1.6 CFM mechanical roughing pump
  • Mounting frame, on casters with air-cooler
  • Wide range vacuum gauge (atmosphere to 10-8 Torr) with digital display
  • 5-foot flexible stainless steel pumping line
  • Vacuum isolation valve
  • Manual turbo pump stand height adjustment
 

TP-TW70H-MOT

  • Turbo pump with nominal
    60 liters/second capacity
  • 1.6 CFM mechanical roughing pump
  • Mounting frame, on casters with air-cooler
  • Wide range vacuum gauge (atmosphere to 10-8 Torr) with digital display
  • 5-foot flexible stainless steel pumping line
  • Vacuum isolation valve
  • Motorized turbo pump stand height adjustment
TP-TW70H-MOT turbo pump station with motorized stand height adjustment

Table of Contents

Page
Introduction 1
Flexible Helium Transfer Lines 2
Liquid Helium Storage Dewars and Accessories 3
Liquid Nitrogen Storage Dewars 4
Mechanical Pumping Stations 5
High Vacuum Pumping Stations 6
Temperature Controllers 7
LHe & LN2 Level Indicators

8

Cryostat Accessories

9

Parts List (including Epoxies, Greases, Wire, etc.)

10

Next Page Janis Products Contact Janis Research Back to Janis Research Home Page

JANIS RESEARCH COMPANY, INC.
2 Jewel Drive, P.O. Box 696
Wilmington, MA 01887-0696 USA
TEL: +1-978-657-8750   FAX: +1-978-658-0349
E-Mail: sales@janis.com
Policies